Installation and maintenance by specialist technicians
Warranty and genuine spare parts
Features
In-line mounted oval gear pulse transmitter, designed to provide accurate measurement signals to external fluid management and control systems.
High-precision measurement using oval gears.
For private use only.
Supplies pulses to external electronics via two output channels.
Intended for use in measuring diesel, petrol, biodiesel, aviation fuel and other liquids compatible with the unit’s construction materials. Certified for use in explosive atmospheres containing gases up to Group IIC.
This equipment has been designed and certified for installation in hazardous areas (Group II) classified as Zone 0, Zone 1 and Zone 2, in accordance with standard EN 60079-10-1.
Due to its T6 temperature classification, the maximum surface temperature of the equipment does not exceed 85 °C. Users must ensure that the characteristics of the fluid and the environment are compatible with the device’s EPL protection level.
The ATEX marking is permanently engraved engravedthe rating plate of the equipment. Users must check that the classification is compatible with the installation requirements.
The equipment has two certified protection modes: Ex ma (encapsulation) and Ex ia (intrinsic safety). The specific installation and usage conditions associated with each protection mode are described in the instruction manual.
This equipment is subject to the conditions of use specified in the EU Type Examination Certificate. For installations in Zone 0 (EPL Ga), compliance with the limitations and special conditions set out in the instruction manual is mandatory.