Installation and maintenance by specialist technicians
Warranty and genuine spare parts
The DFV is a vacuum leak detector for the integrally-bunded tanks according to the EN 13160-1, Class 1 Regulation.
It can be used for both buried and aerial tanks whenever it is in an atmospheric pressure.
This kit is suitable to be used in diesel tanks with a diameter not higher than 2,900 mm. For different densities, heights and/or liquids ask for our Technical Department.
It creates a depression of -400 mbar between the inner wall and the exterior one of the integrally-bunded tank. When the depression decreases under approx. -340 mbar, it has an alarm.
Technical Specifications
Weight (approx.): 1.1 kg
Dim. (approx.): 202x70x230 mm (LxWxH)
Acoustic emission: min. 70 db(A)
Maximum relay intensity: 2 A · 250 VAC (resistive)
Pump stop: -380 mbar
Alarm activation: -325 to -355 mbar
Working temperature: -5 ºC to +50 ºC
Voltage: 100 - 240 VAC ±10 %
Power: 10 VA
Protection: IP-30
Electromagnetic compatibility: Noise immunity: EN 61000 Interference: CISPR22